Applications

AI Data Center

High-efficiency, scalable power conversion for next-generation AI infrastructure.

Overview

AI racks are climbing past 100 kW, and hyperscalers are moving to 800 V DC distribution and medium-voltage grid interfaces to feed them — placing 1200 V SiC at the centre of the new power architecture. DICIO supports the full path from grid to GPU: 3.3 kV SiC GridFRAME 2 for solid-state transformers and MV cells, 1200 V and 1700 V modules for facility rectifiers, three-level UPS and battery interfaces, and 1200 V SiC MOSFETs in top-side-cooled MO-354 and TO-247 packages for high-density rack PSUs, LLC / CLLC and DAB stages. Higher switching frequency and lower loss translate directly into rack power density and PUE.

01 · MARKET GROWTH

AI servers are driving SiC growth in power supplies

The shift to 800 V DC distribution and 1 MW racks is raising the bar for power density and conversion efficiency.

AI data-center power semiconductor market outlook

Market size ($M)

UPS IGBT $337.2MPSU SiC $708.8MUPS SiC $50.5M
02004006008002021202220232024202520262027202820292030
IGBT — UPSSiC — server and rack PSUsSiC — UPS
+125%

SiC for PSUs

Increase in the SiC power-supply device market in 2025

About $128M in 2024 → about $288M in 2025 · $740M in 2031

$16B

Datacom and UPS

2030 datacom converter market

About $7B in 2024 · 15.6% CAGR / UPS about $16B · 6.9% CAGR

800V DC

Next-generation distribution

High-voltage DC distribution inside data centers

Transitioning from 48 V distribution as rack power exceeds 100 kW

Power conversion architecture

From Medium-Voltage Grid to AI Processors

Power from the medium-voltage grid reaches the racks through facility rectifiers and the DC distribution network, where rack power supplies convert it into the low-voltage power required by GPUs and CPUs.

Medium-voltage grid

The medium-voltage AC grid that supplies power to large-scale AI data centers.

System
Data center campus power
Grid voltage
13.8kV · 22kV AC

Engineered value

Performance you can verify

Review the engineering values that matter when selecting a device, then connect each requirement to a product and its operating condition.

Key Applications

  • AI Server & Rack PSU

  • 800V DC Distribution (Sidecar Racks)

  • UPS & Battery Backup (BBU / BESS)

  • MV Solid-State Transformer

  • Facility AFE Rectifier

  • 48V Bus Converter

Key Topologies and Recommended Products

Stage / system
Facility AC to 800 V DC · 100 kW–MW power block
Device class
1200 V SiC MOSFET · Hybrid
3-phase AFE / 3-Level PFC rectifier circuit diagram

Looking for a module for this application?

Tell us your voltage, current and topology and our team will recommend a module or propose a custom design.